Computational Model of Nano-Pharmacological Particles for the Clinical Management of Stenotic and Aneurysmatic Coronary Artery in the Human Body

Authors

  • Ibrahim Fetuga University of Lagos
  • Dr. Olabode Thomas Olakoyejo Department of Mechanical Engineering, University of Lagos
  • Dr. Omotayo Oluwatusin Department of Mechanical Engineering, University of Lagos
  • Dr. Adekunle Adelaja Department of Mechanical Engineering, University of Lagos
  • Joshua Gbegudu Department of Mechanical Engineering, University of Lagos
  • kolade Aderemi Department of Mechanical Engineering, University of Lagos
  • Ebenezer Adeyemi Department of Mechanical Engineering, University of Lagos

Keywords:

Stenosis, Aneurysm, Nanoparticles, Nusselt number, Skin friction coefficient

Abstract

This work presents a three-dimensional computational study of nanoparticles (metallic and non-metallic) suspended in blood flowing through a diseased artery with both stenosis and aneurysm. From the perspective of pharmacodynamics and heat transfer, the influence of nanoparticles on hemodynamic indicators was investigated in a diseased artery. The blood was flowing fluid, steady-state, incompressible, homogeneous, and Newtonian, while the artery was a rigid wall. The three-dimensional continuity, Navier-Stokes, and energy equations were solved numerically by using a RAN-based standard k-ω model, which was performed on the ANSYS commercial software package. The influence of different selected nanoparticles (Al2O3, CuO, SiO2, and ZnO), nanoparticle concentration (1.0%-4.0%), and nanoparticle diameters (25 nm - 100 nm) on hemodynamic parameters such as velocity, temperature, turbulence intensity, more particularly skin friction coefficient and Nusselt number of the blood flow on the diseased artery, was also investigated. The streamlines, contours, and plots were adopted to better visualize the blood flow behavior in an artery with stenosis and aneurysm. The numerical results revealed that at a 4.0% nanoparticle concentration, CuO nanoparticles greatly reduced the blood velocity by 1.96% compared to other nanoparticles. About 0.66%-2.05% reduction in the blood velocity could be achieved by increasing the nanoparticle concentration from 1.0% to 4.0%. The SiO2 blood nanofluid showed the best result in augmentation of the Nusselt number by 53.0%. However, the nanoparticle diameter and concentration showed an insignificant effect on the skin friction factor

References

El Bécaye Maïga, S.; S.J. Palm; C.T. Nguyen; G. Roy and N. Galanis. (2005). Heat transfer enhancement by using nanofluids in forced convection flows. International Journal of Heat and Fluid Flow, 26(4): 530-546. doi: 10.1016/j.ijheatfluidflow.2005.02.004.

Bluestein, D.; L. Niu; R.T. Schoephoerster and M.K. Dewanjee. (1996). Steady Flow in an Aneurysm Model: Correlation Between Fluid Dynamics and Blood Platelet Deposition. Journal of Biomechanical Engineering, 118(3): 280–286. doi: 10.1115/1.2796008.

Casson, N. (1959). A Flow Equation for Pigment-Oil Suspensions of the Printing Ink Type. Rheology of disperse systems, 84–102.

Choi, S. U.S.; Z.G. Zhang; W. Yu; F.E. Lockwood and E.A. Grulke. (2001). Anomalous thermal conductivity enhancement in nanotube suspensions. Applied Physics Letters, 79(14): 2252. doi: 10.1063/1.1408272.

Choi, S. U. S.; S. Li and J. A. Eastman. (1999). Measuring Thermal Conductivity of Fluids Containing Oxide Nanoparticles. Journal of Heat Transfer, 121(2): 280–289. doi: 10.1115/1.2825978.

Dittus, F.W. and Boelter, L.M.K. (1985). Heat transfer in automobile radiators of the tubular type. International communications in heat and mass transfer, 12(1): 3–22.

Ellahi, R.; S.U. Rahman.; S. Nadeem and N.S. Akbar. (2014). Blood flow of nanofluid through an artery with composite stenosis and permeable walls. Applied Nanoscience (Switzerland), 4(8): 919–926. doi: 10.1007/S13204-013-0253-6/FIGURES/17.

Frank-Ito, D. O. and Cohen, S. M. (2021). Orally Inhaled Drug Particle Transport in Computerized Models of Laryngotracheal Stenosis. Otolaryngology–Head and Neck Surgery, 164(4): 829–840. doi: 10.1177/0194599820959674.

Gosman, R. E.; R. M. Sicard; S. M. Cohen. and D. O. Frank‐Ito. (2022). Comparison of Inhaled Drug Delivery in Patients With One- and Two-level Laryngotracheal Stenosis. The Laryngoscope, 133(2): 366-374. doi: 10.1002/LARY.30212.

Hamilton, R. L. (1962). Thermal conductivity of heterogeneous two-component systems. Industrial and Engineering Chemistry Fundamentals, 1(3): 187–191. doi: 10.1021/I160003A005/ASSET/I160003A005.FP.PNG_V03.

Karimi, M.; H. Zare; A. Bakhshian; N. Yazdani; M. Hamrang; E. Mohamed; P.S. Zangabad; S. Masoud; M. Basri; L. Bakhtiari and M.R. Hamblin. (2016). Nanotechnology in diagnosis and treatment of coronary artery disease. Nanomedicine, 11(5): 513–530. doi: 10.2217/NNM.16.3.

Karimi, S.; M. Dadvar; M. Dabagh; P. Jalali; H. Modarress and B. Dabir. (2013). Simulation of pulsatile blood flow through stenotic artery considering different blood rheologies: comparison of 3d and 2d-axisymmetric models. Biomedical Engineering: Application, Basis and Communications, 25(2): 1350023. doi: 10.4015/S1016237213500233.

Keith, L.; A. Moore and A.M.R. Agur. (2009). Clinically Oriented Anatomy. Lippincott Williams & Wilkins.

Kent, K. C. (2014). Clinical practice: Abdominal aortic aneurysms. The New England journal of medicine, 371(22): 2101–8. doi: doi: 10.1056/nejmcp1401430/suppl_file/nejmcp1401430_disclosures.pdf..

Manca, O.; S. Nardini; D. Ricci and S. Tamburrino. (2012). Numerical investigation on mixed convection in triangular cross-section ducts with nanofluids, Advances in Mechanical Engineering, 4: 139370. doi: 10.1155/2012/139370.

Mandal, D. K.; P. Goswami; N. Biswas and N. K. Manna. (2022). Fluid Mechanics in Arterial Diseases: Computational Study. In Advances in Computational Approaches in Biomechanics, 153-178. IGI Global. doi: 10.4018/978-1-7998-9078-2.CH010.

Masoumi, N.; N. Sohrabi and A. Behzadmehr. (2009). A new model for calculating the effective viscosity of nanofluids. Journal of Physics D: Applied Physics, 42(5): 055501. doi: 10.1088/0022-3727/42/5/055501.

Masuda H.; A. Ebata and K. Termae (1993). Alteration Of Thermal Conductivity And Viscosity Of Liquid By Dispersing Ultra-Fine Particles. Dispersion of Al2O3, SiO2 and TiO2 Ultra-Fine Particles. 7(4): 227–233.

Mekheimer, K. S.; M. H. Haroun and M. A. El Kot. (2011). Induced magnetic field influences on blood flow through an anisotropically tapered elastic artery with overlapping stenosis in an annulus. Canadian Journal of Physic, 89(2): 201–12. doi: 10.1139/P10-103.

Nadeem, S. and Ijaz, S. (2015). Theoretical analysis of metallic nanoparticles on blood flow through stenosed artery with permeable walls. Physics Letters A, 379(6): 542–554. doi: 10.1016/J.PHYSLETA.2014.12.013.

Pak, B. C. and Cho, Y. I. (2007). Hydrodynamic and heat transfer study of dispersed fluids with submicron metallic oxide particles. Experimental Heat Transfer, 11(2): 151–170. doi: 10.1080/08916159808946559.

Peyghambarzadeh, S. M.; S. H. Hashemabadi; S. M. Hoseini and J. M. Seifi (2011). Experimental study of heat transfer enhancement using water/ethylene glycol based nanofluids as a new coolant for car radiators. International Communications in Heat and Mass Transfer, 38(9): 1283–1290. doi: 10.1016/j.icheatmasstransfer.2011.07.001

Pincombe, B. and Mazumdar, J. (1997). The effects of post-stenotic dilatations on the flow of a blood analogue through stenosed coronary arteries. Mathematical and Computer Modelling, 25(6): 57–70. doi: 10.1016/S0895-7177(97)00039-3.

Rhee, J. W. and Wu, J. C. (2013). Advances in nanotechnology for the management of coronary artery disease, Trends in Cardiovascular Medicine, 23(2): 39–45. doi: 10.1016/J.TCM.2012.08.009.

Smith, F. T. (1979). The separating flow through a severely constricted symmetric tube. Journal of Fluid Mechanics, 90(4): 725–754. doi: 10.1017/S0022112079002500

Ul Haq, U.; A. Ahmed; Z. Mustansar; A. Shaukat; S. Cukovic; F. Nadeem and L. Margetts. (2022). Computational modeling and simulation of stenosis of the cerebral aqueduct due to brain tumor. Engineering Applications of Computational Fluid Mechanics, 16(1): 1018-1030. doi: 10.1080/19942060.2022.2056511.

Waqas, H.; U. Farooq; D. Liu; M. Alghamdi; S. Noreen and T. Muhammad. (2022). Numerical investigation of nanofluid flow with gold and silver nanoparticles injected inside a stenotic artery. Materials & Design, 223: 111130. doi: 10.1016/J.MATDES.2022.111130.

Yi, J.; F. B. Tian; A. Simmons and T. Barber (2022). Impact of Modelling Surface Roughness in an Arterial Stenosis. Fluids, 7(5): 179. doi: 10.3390/FLUIDS7050179.

Published

2023-05-15

Most read articles by the same author(s)