Placement of Distributed Generation and Shunt Capacitor in Distribution Network using Cuckoo Search Algorithm
Keywords:
Distributed generation, Shunt capacitor, Cuckoo Search Algorithm, Power loss, Voltage stability indexAbstract
This work aims at reduction in active and reactive power loss reduction in distribution networks as well as to improve the voltage stability of the networks. Optimum Distributed Generation (DG) placement and sizing is carried out in conjunction with shunt capacitor placement and sizing to determine the appropriate sizes of DG units and Capacitor banks to be placed in the networks so as not to violate certain constraints. The optimal sizes of the DG units and capacitor banks were obtained on application of a Cuckoo Search Optimization Algorithm while computations for Voltage stability was performed using the Voltage Stability Index (VSI). The obtained optimal sizes of DG units and Capacitors were individually and simultaneously placed on the distribution networks to ascertain the behaviour of the networks prior to and after their placements. The performance factors considered are power loss and voltage stability. A comparison of these performance factors under separate and simultaneous placement method was demonstrated using IEEE 33 and 69 test buses. Result show that power loss (active and reactive) reduced by 63.29% and 59.38% respectively for 33 bus system, with a 74.29% and 79.19% reduction on 69 bus system. Voltage stability also increased by 7.89% and 3.79% respectively for 33 and 69 bus system relative to values obtained for base case and separate DG and shunt capacitor placement.
References
Ackerman, T; G. Anderson and L. Soder. (2001). Distributed Generation Literature Review”, Electric Power System Research, 57(2): 195-204.
Aman, MM; G.B. Jasmon; A.H.A. Bukar and M. Mokhlis. (2013). Optimal Simultaneous DG and Capacitor bank Placement on the Basis of Minimization of Power Losses. IJCEE, 5(5): 516- 522.
Archarya, N; P. Archarya and N. Mithulananthan. (2006). An Analytical Approach for DG Allocation in Primary Distribution Network. International Journal of Electrical Power & Energy systems, 28(10): 669-678.
Charkravorty, M. and Das, D. (2001). Voltage Stability Analysis of Radial Distribution Networks. International Journal Electrical Power and Energy System, 23(5): 35-129.
El-Khattam, W. and Salama, M.M.A. (2004). Distributed Generation Techniques, Definitions and Benefits. Electrical Power Systems Research, 71(1): 119-128.
Esmaeilian, H.R; O. Darijany and M. Mohammadian. (2014). Optimal Placement and Sizing of DG units and Capacitors Simultaneously in Radial Distribution Networks Based on Voltage Stability Security Margin. Turkish Journal of Electrical Engineering and Computer Science, 5(2): 1-14.
Khodr, H.M; F.G. Olsina and J.M. Yusta. (2008). Maximum Savings Approach for Location and Sizing of Capacitors in Distribution Systems.Electric Power Systems Research, 78(3): 1192- 1203.
Kowsalya, M. (2014). Optimal Distributed Generation and Capacitor Placement in Power Distribution Networks for Power Loss Minimization. International Conference on Advances in Electrical Engineering (ICAEE), 4: 1-5.
Lund, T. (2007). Analysis of Distribution Systems with a high penetration Distributed Generation. PhD. Thesis, Centre for Electric Technology (CET), Technical University of Denmark.
Pepermans, G; J. Driesen; D. Haeseldonckx; R. Belmans and W. D‟haeseleer. (2005). Distributed Generation: Definition, Benefits and issues. Energy Policy, 33(6): 787-798.
Pereira, L. (2004). Cascade to System Blackouts. Power and Energy Magazine IEEE 2(2): 54-57.
Rahiminejad, M; A. Aranizadeh and B. Vahidi. (2014). Simultaneous Distributed Generation and Capacitor Placement and Sizing in Radial Distribution System Considering Reactive Power Market. Journal of Renewable and Sustainable Energy, 6(4): 43 – 124.
Sumit, B; C.K. Chanda and S.C. Konar. (2010). Determination of the Weakest Branch in a Radial Distribution System using Reactive Loading. Joint International Conference on Power Electronics Drives and Energy Systems, New Delhi, India, 1-5.
Yang, X.-S. (2010). Cuckoo Search via Levy Flights. World congress on nature and biologically inspired computing (WaBIC), 210-214.
Yuvaraj, T. (2015). D-STATCOM Allocation in Distribution Networks Considering Load variations using Bat Algorithm. Ain Shams Engineering Journal, 8(3): 391-403.
Additional Files
Published
Issue
Section
License
Copyright (c) 2020 Nigerian Journal of Technological Development
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
In accordance with the Copyright Act of 1976, which became effective January 1, 1978, the following statement signed by each author must accompany the manuscript submitted: "I, the undersigned author, transfer all copyright ownership of the manuscript referenced above to the Nigerian Journal of Technological Development, in the event the work is published. I warrant that the article is original, does not infringe upon any copyright or other proprietary right of any third party, is not under consideration by another journal, and has not been published previously. I have reviewed and approve the submitted version of the manuscript and agree to its publication in the Nigerian Journal of Technological Development." A copyright transfer form should be downloaded from the NJTD Website ( http://njtd.com.ng/index.php/njtd). Author(s) will be consulted, whenever possible, regarding republication of material. All authors must have access to the data presented and the authors and sponsor (if applicable) must agree to share original data with the editor if requested.